Machine actions Causes Solutions
The machine grinds the co ee beans
but no co ee comes out.
(See note)
There is no water. Fill the water tank and prime the circuit (see "Us-
ing the Machine for the First Time" chapter).
The brew group is dirty. Clean the brew group (see the "Weekly Cleaning
of the Brew Group" chapter).
The circuit is not primed. Prime the circuit (see "Using the Machine for the
First Time" chapter).
This might occur when the machine is
automatically adjusting the dose.
Brew a few cups of co ee as described in the
“Saeco Adapting System” chapter.
The dispensing spout is dirty. Clean the dispensing spout.
Co ee is too weak.
(See note)
This might occur when the machine is
automatically adjusting the dose.
Brew a few cups of co ee as described in the
“Saeco Adapting System” chapter.
Co ee is brewed slowly.
(See note)
The co ee grind is too ne. Change co ee blend or adjust the grind as
explained in chapter "Adjusting the Ceramic
Co ee Grinder".
The circuit is not primed. Prime the circuit (see "Using the Machine for the
First Time" chapter).
The brew group is dirty. Clean the brew group (see the "Weekly Cleaning
of the Brew Group" chapter).
Co ee leaks out of the dispensing
spout.
The dispensing spout is clogged. Clean the dispensing spout and its holes.
Milk does not froth. The Automatic Milk Frother is inserted too
deep. No milk is being suctioned.
Leave the Automatic Milk Frother to cool down.
Move it slightly downwards. Reposition it in its
correct seat.
Frothed milk is too cold. The cups are cold. Preheat the cups with hot water.
Note:
These problems can be considered normal if the co ee blend has been
changed or if the machine has just been installed. In this case wait until the
machine performs a self-adjusting operation as described in "Saeco Adapt-