Sears 32025 Cooktop User Manual


 
PREPARATION
Adequate counterspace must be provided for the unit.
The area should be easy to reach and be lighted with
natural light during the day.
See the first page for cutout dimensions. Mark the cutout
on the counter. Use a hand or saber saw to make the cut.
ELECTRICAL CONNECTIONS
Call your Electric Company and ask which codes apply
In your area. If there are no codes, you must follow the
NATIONAL ELECTRICAL CODES, ANSI/NFPA NO. 70-
Latest Edition. You can get a copy by wrlUng:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
The counter unit cord has a three prong plug and must
be plugged Into a properly grounded three hole outlet.
The outlet must be In a standard 120 Volt, 60 Hertz AC
household circuit.
Improper grounding can spark Ignition on models so
equipped.
Do not under any circumstances
cut or remove the grounding prong
from the counter unit cord. Failure
to provide proper polarization may
cause shock and tire hazard.
If you do not have a grounded three hole outlet, have an
electrician change your old outlet or Install a new one.
TO temporarily use a properly polarized and grounded
two hole outlet until a grounded three hole outlet can be
Installed, a grounding adapter plug may be used. Have
an electrician test the outlet to be sure It meets require-
ments.
PLUG WITH GROUND PRONG
PROPERLY POLARIZED AND
GROUNDED RECEPTACLE
POLARIZED RECEPTACLE
PROPERLYGROUNDED
METAL EYELET
GROUND
RECEPTACLE
PLATE
MOUN_NG
SCREW
GAS CONNECTIONS
Call your gas supplier and ask which codes apply Inyour
area. If there are no codes, you must follow the NA-
TIONAL FUEL GAS CODE, ANSIiZ223.LStest Edition.
You can get a copy by writing:
American Gas Association
1515 Wilson Boulevard
Arlington (Rosslyn), VA 22209
Know where your main gas shut off valve Is.
Shut off gas supply before removing an old range. Leave
It off until hookup of new counter unit Is finished.
See figures on this page for rigid and flexible pipe
hookups. Some local codes do not allow the use of
copper gas pipe. If flexible connectors are allowed,
a new A.G.A. certified flexible connector is rec.
omrnended. Never reuse an old connector when
installing a new unit. A manual shut-off valve, for
the purpose of turning on or shutting off the gas
supply to the appliance, must be installed in the
gas supply line at anaccessible location in the
cabinet below the counter unit.
We recommend that you use 1/2" gas supply line.
1"FROM BACKWALL
.<_121/2,_,_
_ FROMCUTOUT
CENTER UNE
LOCATION OF GAS SUPPLY LINE
FIG.3
Fig. 1
PREFERRED METHOD
Fig. 2
TEMPORARY METHOD
5 NGINS19