Check the following before calling service:
1.Does the display light? Yes.__ No.__
2.When the door is opened, does the oven light come on? Yes__ No.__
3.Place one cup of water in a glass measureing cup in the oven and close the
door securely.
Operate the oven for one minute on 100% (HIGH) :
A. Does the oven light come on? Yes__ No.__
B. Does the cooling fan work? Yes.__ No.__
(Put your hand over the rear ventilation openings.)
C. Does the turntable rotate? Yes.__ No.__
(It is normal for the turntable to turn either direction.)
D. Does the COOK indicator light? Yes.__ No.__
E. After one minute, did an audible signal sound? Yes__ No.__
F. Is the water in the oven warm? Yes.__ No.__
4. Remove water from the oven and program the oven for 3 minutes on GRILL
option number 1.
A. Do the top and bottom heater symbols and COOK indicator light?
B. After 3 minutes, does the oven feel hot? (Pay special attention to
prevent burns when checking the bottom heater.)
Yes__ No.__
Yes__ No.__
if "NO" is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit
breaker, if they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER.
A microwave oven should never be serviced by a "do-it-yourself" repair person.
NOTE: If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 22
and cancel.
AC Line Voltage: Single phase 120V, 60Hz, AC only
AC Power Required:
Microwave 1450W 12.5 A
Grill/Convection 1550W 13.0 A
Frequency: 2450 MHz
Outside Dimensions: 201/2"(W) x 12W'(H) x 193/4"(D)
Cavity Dimensions:** 137/8"(W) x 71/2"(H)x 141/2"(D)
Oven Capacity:** 0.9 Cu.Ft.
Cooking Uniformity: Turntable system, 12 3/4"diameter
Weight: Approx. 44 Ib
* The International Electrotechnical Commission's standardized method for measuring output wattage. This
test method is widely recognized.
*-.k- Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding
food is less.
In compliance with standards set by:
FOC - Federal Communications Commission Authorized.
DHHS - Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I,
Subchapter J.
- This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
23