Sub-Zero Downdraft Ventilation Ventilation Hood User Manual


 
7
INSTALLATION INSTRUCTIONS
Models ICBDD45I and ICBDD45R
1156 mm
1048 mm
60 mm
230 mm
38 mm
DEPTH OF
DOWNDRAFT CHIMNEY
ELECTRICAL REQUIREMENTS
Wolf downdraft ventilation systems require a
separate, 240 V 50/60 Hz power supply. The
service should have its own 10A circuit
breaker. The unit is supplied with a 2.5 m CEE
7/7 “Schuko” style Continental European
power cord. The specific location of the outlet
is not critical, as long as it is within reach of
the power cord that is located mid-way, top
and bottom, on the right side of the downdraft.
IMPORTANT NOTE:
If Model ICBDD30 is to be
installed in a 762 mm wide cabinet, Model
ICBDD36 in a 914 mm wide cabinet or Model
ICBDD45 in a 1156 mm wide cabinet, the
electrical outlet cannot be located on the back
wall of the cabinet. The outlet can be placed in
an adjacent cabinet within reach of the power
cord. An access hole for the power cord must
be drilled in the cabinet wall.
Choose the electrical location shown in
the illustration below that best suits your
installation.
Location of electrical
914 mm min
FOR MODEL ICBDD36
1156 mm min
FOR MODEL ICBDD45
762 mm min
FOR MODEL ICBDD30
OPTIONAL
ELECTRICAL
LOCATION IN
ADJACENT RIGHT
SIDE CABINET
E
OVERALL DIMENSIONS
MODELS ICBDD45I AND ICBDD45R
Overall Width 1156 mm
Width of Chimney 1048 mm
Overall Height
(above countertop)
230 mm
Overall Depth 60 mm
Depth of Chimney 38 mm
Dimensions may vary to
+
3 mm.
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.