Taylor 750 Frozen Dessert Maker User Manual


 
26
Models 750, 751, 754, 774, 791, 794Operating Procedures
080602
Install the air orifice into the hole in the top of the air
tube (in the end without the small hole on the side).
Figure 21
Step 11
Lay the air tube (with the air orifice installed) and the
hopper gasket i n the bottom o f the mix hopper for
sanitizing.
Note: The Models 754 and 774 have one hopper
gasket for each mix hopper . The Models 791 and 794
do not require a hopper gasket.
Repeat steps 10 and 11 for the other side of the
freezer on Models 754, 774, 791, and 794.
Sanitizing
Step 1
Prepare an approved 100 PPM sanitizing solution
(examples: 2--1/2 gal. [9.5 liters] of Kay--5 R or 2
gal. [7.6 liters] of Stera--SheenR). USE WARM WA-
TER AND FOLLOW THE MANUF ACTURER’S
SPECIFICATIONS.
Step 2
Pour the sanitizing solution into the hopper and allow
it to flow into the freezing cylinder .
Figure 22
Step 3
While the solution is flowing into the freezing cylinder ,
brush clean the mix hopper. When cleaning the
hopper, take particular care in brushing the mix level
sensing probe on the rear wall of the hopper, the mix
inlet hole, the air tube, and the hopper gasket.
Figure 23
Figure 24