28
Model C300Operating P rocedures
Draining Product From the
Freezing Cylinder
Step 1
With a pail beneath the door spout, press the
BEATER (- - - ) key. This will allow the beater to
operate and CO
2
pressure will be maintained to
push the product f rom t he freezing cylinder. Open
the d raw valve and drain the product from the
machine until the CO
2
begins to jet.
Figure 42
Step 2
When all the product has been dr ained from the
freezing cylinder, close the draw valve and press the
OFF ( <- - ) key. Discard this pr oduct.
Figure 43
Repeat Steps 1 and 2 for the other freezing
cylinder.
Rinsing
Step 1
To plac e the left cylinder in the RINSE mode, press
the MENU (SEL) key. Move the cursor by pressing
the AUT O (- - >) k ey until the third line indicates
RINSE / SANITIZE.
OPERATOR MENU
ABCDEFGH
I
RINSE / SANITIZE
<- - - -> SEL
Press the MENU (SEL) key. Move the cursor under
“RINSE” by pressing the OFF (<- - ) k ey twice.
RINSE / SANITIZE
RINSE SANITIZE EXIT
----
<- - - -> SEL
Step 2
Pressing the MENU (SEL) key will give you the
option for rinsing the left freezing c ylinder. Move the
cursor under the word “YES”. Pressing the MENU
(SEL) key at this time will start the beater motor and
deliver water and CO
2
to the left c ylinder.
RINSE
LEFT SIDE YES NO
---
<- - - -> SEL
Step 3
Allow the rinse water to flow into the cylinder until it
is approximately 2/3 full. With a pail under the door
spout, open t he draw valve and drain the rinse
water. Repeat this procedure until the rinse water
being drawn i s clear.
Repeat Steps 2 - 3 for the right side.
RINSE
RIGHT S IDE YES NO
---
<- - - -> SEL
When draining is complete, press the OFF (<- - )
key.