SET-UP PROCEDURE
1) Pre-mix cleaning solution as required for specific application in a five gallon (19 liter) pail. Pour pre-mixed solution through
solution fill hole of system (page 3, #2).
NOTE: This system has a built-in solution heat maintenance feature, start with hot water if possible. Hot water is hygienic
and maximizes cleaning potential.
2) Add appropriate amount of defoamer to the recovery tank (page 3, #3).
3) Connect end of the vacuum hose to the vacuum inlet connector (page 3, #8).
4) Connect male end of the solution hose to female quick-connect coupling (page 3, #6), and female end of solution hose to
the male end of the cleaning wand.
5) With solution tank full and vacuum and solution hoses properly connected, plug main power cord (page 3, #5) into properly
grounded outlet.
NOTE: Plug the cord into an outlet that will be out of the way of the cleaning path, ideally a 20 amp circuit when available.
6) Your system is now ready for operation.
7) Once pre-spray, furniture removal and other carpet preparation is complete, proceed to clean carpet and/or upholstery.
NOTE: Vacuum and pump switches can now be activated to “ON” position.
EXTRACTION CLEANING PROCEDURE
1) With solution tank full and all hoses appropriately attached, activate pump switch to the “ON” position, then activate the
vacuum switch to the “ON” position.
2) Start in area of the room opposite from where you want to end.
3) Place wand about 4 feet in front of you.
4) Activate the solution spray trigger of wand.
5) Laying down an even spray of solution, pull the wand back towards you slowly.
6) Release the solution spray trigger and move the wand slowly forward over the same area just cleaned to recover additional
solution left behind. Repeat this process several times depending on the degree of carpet soiling then move over the width
of the wand, overlapping slightly to prevent streaking. For best results, work in approximately 4 foot wide sections and
always be sure to remove as much solution from the carpet as possible as this will minimize drying time.
7) When solution tank is empty and needs refilling, shut system down and repeat step 1 of “Set Up Procedure”.
8) Remove, empty and replace recovery holding tank. (page 3, #3).
NOTE: Always empty and replace recovery tank at the same time you refill the solution tank.
9) Add more defoamer into the recovery holding tank (step 2 of “Set Up Procedure”).
NOTE: With solution tank full and recovery tank empty, the system is now ready to continue cleaning. Continue the process
until cleaning is complete.
5