OPERATING INSTRUCTIONS
1. Push ON/OFF rocker switch to “ON” position.
2. Push HEAT/PROOF switch to HEAT for heating.
3. Turn HEAT thermostat knob fully clockwise for pre-heat.
4. Allow 45 minutes for pre-heating, then turn thermostat to desired setting.
5. For proofing, push HEAT/PROOF switch to PROOF.
6. Adjust the heat and humidity thermostat knobs to control desired temperature and humidity.
Allow 45 minutes for pre-heating.
NOTE: The internal air circulation blower will operate continuously when the power switch is
turned “on”.
HEAT THERMOSTAT -
The controlling range is 80°F to 175°F. The dial has numbers 1 through 9 that do not relate to
specific calibrated temperatures. Temperature settings must be obtained through familiarization
with the unit. The dial has an “off” position to turn heater unit off.
HUMIDITY THERMOSTAT -
To control humidity range from 30% to 100% humidity, settings must be obtained through
familiarization with the unit. The dial also has an “off” position to turn heater unit off.
To maintain low heat range between 85°F and 100°F, switch to proof mode and adjust heat knob
to desired heat range. Allow 45 minutes to pre-heat in proof cycle.