Verona VECTEM365 VECTEM304 Cooktop User Manual


 
ENGLISH
Use & Care Manual
11
The control uses only the 15% of the available power,
divided in 0 to 9 steps with a better accuracy.
Keep in mind that power level 9 in this special mode
correspond exactly to level 4 in the standard range.
Select the zone and touch the [LOW TEMP] key again
in order to disable the Low Power Scale and restore the
standard one, without switching off the zone.
Pay attention: the level remains the same but the
power increases.
Switching off a cooking zone as described below
disables the Low Power mode. When the zone will be
selected again it will start to work in the standard power
mode.
Switching an element off
Touch the related [OFF] key (ref.1) in order to stop a
heating element.
You may turn off all active elements at the same time by
touching the main [ON/OFF] key.
Dual element activation
Select a double heating area touching the related [ON]
key, the HOT SURFACE led (ref.3) begins to ash.
Touch the [DOUBLE] key in order to enable/disable the
outer ring of a double zone. This operation is possible
while the HOT SURFACE led (ref.3) is ashing.
The dual element enabling indication (ref.5a) is on
when the element is enabled, is off when the element
is disabled.
Triple element activation
Select a multiple heating area touching the related [ON]
key, the HOT SURFACE led (ref.3) begins to ash.
Touch the [TRIPLE] key in order to enable/disable the
outer rings of a triple zone:
• If only the inner element is enabled, the intermediate
ring is enabled too.
• If the inner and the intermediate elements are
enabled, the outer ring is enabled too.
• If all the elements are enabled, the outer and the
intermediate rings are disabled.
These operations are possible until the HOT SURFACE
led (ref.3) is still ashing.
The intermediate element enabling indication (ref.5a) is
on when the double element is enabled, is off when the
double element is disabled.
The outer element enabling indication (ref.5b) is on
when the triple element is enabled, is off when the triple
element is disabled.
Bridge element activation
Select one of the two single heating areas belonging
to the bridge touching the related [ON] key, the HOT
SURFACE led (ref.3) begins to ash.
Touch the [BRIDGE] key in order to enable the bridge
element and set the whole cooking area as a single
unit.
This operation is possible until the HOT SURFACE led
(ref.3) is still ashing, before or after setting the power
level:
• Set the power level on the selected zone then touch
the [BRIDGE] key; both the displays will show the
same power level and both extension lights (ref.1a,
1b) turns on.
• Touch the [BRIDGE] key, both HOT SURFACE
led (ref.3) begin to ash and both extension lights
(ref.6a, 6b) turns on. Set the power level that will be
immediately and simultaneously displayed on both
displays.
6a
6b
3
3
Figure. 9
Once the bridge conguration is active, the [ON] and
[OFF] keys of the two single zones involved can be
used indifferently to control the bridge area. All actions
will have the same effect on the whole cooking area.
The bridge conguration cannot be disabled while is
active. It’s always necessary to switch the area off: the
bridge will be disabled automatically.
Hot surface indicator light
Each element has a HOT SURFACE indicator light
(ref.3) to show when the cooking area is hot.
This indication turns on when the zone is activated and
remains ON until the cooking area has cooled down to
a “safe to touch” temperature (approximately 150°F).