Verona VECTGV304SS Cooktop User Manual


 
ENGLISH
Installation Manual
20
Proper adjustment will produce a stable, steady blue
flame of minimum size.
The final adjustment should be checked by turning
knob from high to low several times without extin-
guishing the flame.
This adjustment, at low setting, will automatically pro-
vide the proper flame size at medium setting.
After Conversion steps have been completed, check
the appearance of each burner's flame at the HI and
LO settings, if the flames appear too large or too small
review each step to make sure it was completed cor-
rectly.
Electric gas ignition
The gas burner use an electric ignition device located
near each burner that by means a spark igniters en-
sure its surface light automatically.
Figure 22. Electric ignition
See Use & Care manual for better explanation and
its control.
The Burner Flames
Turn each burner on. Flames should be blue in color
with no trace of yellow. The burner flames should not
flutter or blow away from the burner The inner cone of
the flame should be between 1/2" and 3/4" long.
Figure 23. Burner flames
NOTE:
To obtain the correct minimum setting with LP gas,
turn clockwise tightening the valve fully by the
thin-blade screwdriver into the recess at centre of
valve stem.
COOKTOP
BURNER
-1/2” to 3/4”
Burner flames