Viking VIL1200 Ventilation Hood User Manual


 
VIKING MODEL VIL1200
INLINE FAN
ONLY FOR USE WITH: VWH, VIH, VBCV, VICV, DTWL AND
DTWN 24"W TO 66"W WALL AND ISLAND HOODS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer or
your distributor.
2. Before servicing or cleaning unit, switch power off at ser-
vice panel and lock the service disconnecting means to pre-
vent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by
a qualifi ed person(s) in accordance with all applicable
codes and standards, including fi re rated construction
codes and standards.
4.
Suffi cient air is needed for proper combustion and ex-
hausting of gases through the fl ue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer’s guidelines and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5 When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of re, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
3. Please read specifi cation label on product for additional
information and requirements.
4. Unit has an unguarded impeller. Do not use in locations where
the impeller is readily accessible to people or animals.
5. Screen guards must be installed if impeller is within reach
of personnel, and less than 7 feet above the fl oor.
6. When handling fan wear hand protection and stay
clear of sharp edges.
7. Because this unit has rotating parts, safety should be
exercised during all phases of installation, operation and
maintenance.
8. The motor is permanently lubricated. Do not oil or disas-
semble motor.
9. Electrical circuit, including speed control, (if used), must
be rated 5.0 AMPS minimum.
SPECIFICATIONS
MODEL
VOLTS
AMPS
CFM
DUCT SIZE
V
IL1200
115
4.84
1200
10” DIA.
INSTALLER: Leave this Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
1