— 5 —
C24EA SERIES ELECTRIC CONVECTION STEAMERS
ELECTRICAL CONNECTION
WARNING: ELECTRICAL AND GROUNDING
CONNECTIONS MUST COMPLY WITH
APPLICABLE PORTIONS OF THE NATIONAL
ELECTRICAL CODE AND / OR OTHER
LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
The wiring diagram is locatedinside the front panel.
C24EA6 AND C24EA10 CURRENT DRAW
Model Voltage Total kW 3 Phase Single Phase 125% of Minimum Wire Size
L1 L2 L3 Maximum (75°C Cu Wire)
C24EA6 208 16.9 81.25 101.56 3
240 19.0 79.08 98.85 3
208 16.9 46.29 48.16 46.29 60.20 6
240 19.0 42.82 42.82 51.32 64.15 6
480 17.2 20.33 21.41 20.33 26.76 10
C24EA10 208 25.2 121.15 151.44 1/0
240 26.5 110.37 137.96 1/0
208 25.2 69.12 71.61 69.12 89.51 3
240 26.5 67.04 57.09 67.04 83.80 4
480 25.6 30.31 31.75 30.31 39.69 8