MCS-425 Microwave sensor switch
Installation Instruction
Copyright©2008Gianniindustries,inc.Allrightsreserved.
Publishedon2008.08.20P-MU-MCS-425 Ver.C
Relay mode and Jumper Status
Jumper mode
N.O.
N.O.=OPEN
N.O.=OPEN
N.O.=OPEN
N.O.=CLOSED
N.O.=CLOSED
N.O.=OPEN
N.C.=CLOSED
N.C.=CLOSED
N.C.=CLOSED
N.C.=OPEN
N.C.=OPEN
N.C.=CLOSED
LED OFF
LED OFF
LED OFF
LED ON
LED ON
LED OFF
N.C.
Relay Normal Status
Detects the signal
RelayAction Status
No power
Relay Statue
Fig. A The connection for fail-safe Lock devices:
Fig. B The connection for fail-secure Lock devices:
LockingDevice
(fail-safe)
Power Supply
Power Supply
ControlDevice
ControlDevice
Relayoutput
control
Relayoutput
control
+
-
N.C
Com.
N.O.
+
-
N.C
Com.
N.O.
N.C
Com.
N.O.
N.C
Com.
N.O.
Jumper(N.C.)
Jumper(N.C.)
N.C.
N.C.
LockingDevice
(fail-secure)
The diagrams below illustrate the two recommended ways of installing the and access control devices after power input
(power on).
MCS-425 microwave sensor switch can be used with access control system which it can work as a request to exit.
MCS-425
Power Input: 12 V~24VAC/DC (self-regulating)
Maximum current: 80 mA
Frequency: 10.525 GHz
Relay rated 3A, 125VAC / 30VDC
Relay actuation time: 0.5~4Seconds
Sensor Angle: 7.5° ~ 82.5°
Operating Temperature Range: -20°C ~ +55°C
Dimensions: 122.5(W) * 72(H) * 63 (D)mm
Microwave Antenna stand angel: 35°
Jumper: N.O. (Normal open)
Adjustment resistance:
(A) Clockwise turns on switch to is
biggest.
(C) Clockwise turns on switch to
increase the relay actuation time.
Detection Range: 4.5 meter
Specifications
Application
The factory settings
A
C
D
LED
+AC/DC 12~24V
-
N.C
Com.
N.O.
Jumper
N.C.
N.O.
How to use
1.Before turning-on this unit, please make sure all cables are
connected properly.
2.The mounting height is 230 cm.
3.Antenna angle (D) is adjustable, the higher the antenna angle,
the wider the detection range that can be detected. Instead, the
lower the antenna angle, the narrower the detection range that
can be detected.
4.Turn the (A) clockwise to increase the antenna detection range,
or the counter-clockwise turn to decrease the antenna detection
range.
5.Turn the (C) clockwise to increase the relay actuation time, or
the counter-clockwise turn to decrease the relay actuation time.
A
Clockwise turns on switch to is biggest.
Clockwise turns on switch to increase the
relay actuation time. (0.5~4Seconds)
C