Whirlpool DP-009 Microwave Oven User Manual


 
Delivery & Installation Pointer
September 2006
Exhaust Blower Change
New Microwave Hood Combination
(MHC)
(Whirlpool Brand)
DP-009
September 2006
8178602
The newly designed MHC is shipped with the exhaust blower in the recirculation
position. The blower can be rotated for a top discharge or rear discharge by removing
the 2 recessed screws on the rear of the MHC. The 2 visible gold colored screws
under the blower housing are being removed in error.
Procedure to reverse the blower assembly.
1. Locate the 2 screws that loosen the blower assembly. The screws are located in
the holes below the blower assembly (See Figure A.)
BACKGROUND:
ISSUE:
2. Removing the 2 screws will require either a hand screwdriver or a longer phillips
bit for your drill. These screws are recessed into the hole approximately ¾”.
3. Remove the blower assembly and rotate to the desired position. When rotating the
blower it is best to disconnect the wiring harness plug before rotating the blower
assembly. After repositioning the blower reinstall the wiring harness plug.
4. Do not to overtighten the 2 blower screws when reinstalling.
RECESSED SCREWS
DO NOT REMOVE
THESE SCREWS
FIGURE A