Gas Supply Line
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A
smaller size pipe on longer runs may result in insufficient gas supply. With LP
gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas
suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do
not use TEFLON
®†
tape.
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm)
long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may
be used for connecting range to the gas supply line.
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe
threads of the inlet to the appliance pressure regulator.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve
should be located in the same room but external to the range opening, such as
an adjacent cabinet. It should be in a location that allows ease of opening and
closing. Do not block access to shutoff valve. The valve is for turning on or
shutting off gas to the range.
Electrical: A 120-volt, 60 Hz, AC-only, 15 amp, electrical supply fused on both
sides of the line. A separate circuit is recommended. A time-delay fuse or circuit
breaker is recommended.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A.Gas supply line
B.Shutoff valve “open” position
C.To range
A
B
C
29⁷⁄₈" (75.9 cm)
width
46¹⁄₄" (117.5 cm)
overall height for
tall backguard
models
24¹⁄₄" (61.6 cm)
36"
(91.4 cm)
cooktop
height
26¹⁄₄" (67.9 cm)
depth with handle
*** NOTE: 24" (61.0 cm) min. when bottom of wood or metal cabinet is
protected by not less than ¹⁄₄" (6.4 mm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm)
copper.
30
"
(76 2 cm) min clearance between the top of the cooking
Contact a qualified floor covering
installer to check that the floor
covering can withstand at least 200°F.
Use an insulated pad or ¹⁄₄" (6.4 mm)
plywood under range if installing
range over carpeting.
For minimum clearance
to top of cooktop, see
NOTE.***
Do Not seal the range to
the side cabinets.
If cabinet depth is greater
than 24" (61.0 cm), oven
frame must extend
beyond cabinet fronts by
¹⁄₂" (1. 3 cm) min.
18" (45.7 cm) min.
clearance upper
side cabinet to
countertop
13" (33.0 cm)
max. upper
cabinet depth
30¹⁄₈" (76.5 cm)
opening width
30" (76.2 cm) min.
cabinet opening
width
8"
(20.3 cm)
2"
(5.1 cm)
10"
(25.4 cm)
24"
(61 cm)
5"
(12.7 cm)
5"
(12.7 cm)
3"
(7.6 cm)
2" (5.1 cm) min.
countertop space to
side wall or other
combustible material
This shaded area
recommended
for installation of
gas pipe.
This shaded area
recommended for
electrical outlet.
***NOTE: 24" (61.0 cm) min. when bottom
of wood or metal cabinet is protected by
not less than ¹⁄₄" (6.4 mm) flame
retardant millboard covered with not
less than No. 28 MSG sheet steel, 0.015"
(0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) min. clearance between
the top of the cooking platform and the
bottom of an unprotected wood or metal
cabinet.