Wind Crest VEN100E Ventilation Hood User Manual


 
Copyright 2006 Wind Crest by CNP Industries 1
Install Quick Specs are for planning purposes only. Please refer to the detailed installation
instructions, prior to making any cutouts.
Externally Mounted Ventilators – Install Quick Specs
VEN100E
Installation Type & Discharge Direction
Mounted outside. Can be mounted on exterior
roof or wall.
CFM Rating
1000 CFM = VEN100E
Minimum Duct Size
10” round
Maximum Equivalent Straight Duct Length
50 feet
Equivalent Straight Lengths
1 foot of 8” or 10” duct = 1 foot
1 foot of 3 ¼” x 14” rectangular = 1 foot
8” round 90 degree Elbow = 5 feet
10” round 90 degree Elbow = 3 feet
Wall or Roof Cap = 2 feet
Standard Features
Adaptable to all Wind Crest hoods
Weather-resistant galvanized steel
construction
Thermally protected, permanently
lubricated motor
Dynamically balanced 11” diameter blower
wheel
Neoprene resilient anti-vibration mounted
Built-in Flashing plate for roof or wall mount
Easily removed blower cover for periodic
cleaning
Ventilator Motor Ratings*
Hoods without Heat Lamps:
8.0 Amps @ 120 V AC, 60 Hz
Hoods with Heat Lamps:
12.4 Amps @ 120 V AC, 60 Hz
*For maximum power supply required, refer to
hood series selected.
Ventilator Carton Weight:
VEN100E = 80 lbs.