Zanussi 291165 Pasta Maker User Manual


 
ZANUSSI
P R O F E S S I O N A L
CR 40 AUTOMATIC PASTA COOKERS
SPECIAL MACHINES
Supply voltage 230 V, 1N, 50 230 V, 1N, 50
Net weight - kg. 386 345
auxiliary 0.25 0.25
Power - kW
Steam consumption at 0.5 bar - kg/h 100
Basket load capacity - kg 20 20
Number of baskets 2 2
height 410 410
depth 640 640
width 625 625
Usable well dimensions - mm
N° of wells 1 1
height adjustment 50 50
height 850 850
depth 1280 1280
width 1600 1600
External dimensions - mm
Power supply Gas Steam & Electric
CR40G
291164
CR40V
291165
CHARACTERISTICS MODELS
TECHNICAL DATA
RANGE
COMPOSITION
The range consists of 2 gas and steam
models with 1 well and 2 automatically tilting
baskets, ideal for the cooking in water of
pasta, rice, minestrones, boiled meat etc.
FUNCTIONAL AND
CONSTRUCTION
FEATURES
External panelling and load bearing frame in
304 AISI stainless steel. Cooking well with
rounded corners in 316 AISI stainless steel and
fitted with an overflow pipe. The combustion
chamber is in 309 AISI stainless steel (CR/40 G).
Jacketed well in 18/10 stainless steel (CR/40 V)
Cooking basket and all other parts in contact
with water are made from 316 AISI stainless steel
Elevating basket which is automatically tilted
at the end of the cooking cycle by an
electromechanic linear activator fed at low
tension (24 V)
Electrovalve with probe to prevent heating in
the case of no water. Automatic ignition when
water reaches minimum level
Electronic control end limit basket
Automatic water filling and automatic water
topping up
Large drainage tap with insulated handle
positioned on the front of the appliance
Insulated lid and handle in 304 AISI stainless
steel fitted on hinges with counter-balancing
springs
Simple and functional control panel provided
with transparent pexiglass protection.
Tilting lower panel or easily removed front
panels for quick and easy access to the working
parts
Heating by stainless steel burners
Safety valve and flame failure device for
cutting off the gas flow if the pilot light is
accidentally extinguished (CR/40 G)
Automatic electronic ignition (CR/40 G).
All gas appliances are supplied for use with
natural gas (methane), with LPG conversion jets
supplied as standard
Steam supply pressure 0.5 bar (CR/40 V)
Controls and safety unit consisting of safety
valve, depressurising valve and pressure gauge
(CR/40 V)
Steam flow controlled by means of a ball valve
(CR/40 V)
A drainpipe for condensing water for steam
appliances is compulsory
All models comply with the standards required
by the main international approval boards and are
H marked