Zanussi 641259 Ventilation Hood User Manual


 
ZANUSSI
P R O F E S S I O N A L
304 AISI WALL TYPE HOODS
SUPERTREDIL - S line - 1500mm
Net weight - kg. 93 117 136 160 182 203 225 246
Inlet Air Capacity - mc/h 1500 1860 2100 2400 2760 3180 3600 3960
Air Capacity - mc/h 2000 2700 3300 4000 4700 5300 6000 6600
height 500 500 500 500 500 500 500 500
depth 1500 1500 1500 1500 1500 1500 1500 1500
width 1200 1600 2000 2400 2800 3200 3600 4000
External dimensions - mm
STPF1512
641257
STPF1516
641258
STPF1520
641259
STPF1524
641260
STPF1528
641261
STPF1532
641262
STPF1536
641263
STPF1540
641264
CHARACTERISTICS MODELS
TECHNICAL DATA
RANGE
COMPOSITION
A range of hoods exploiting the
"inductive emission" principle.
Untreated air is introduced inside to
partly compensate for that removed.
This results in better drawing of
fumes towards the filter surface and
reduced air-treatment costs. The
range consists of hoods with 8
different lengths (1200, 1600, 2000,
2400, 2800, 3200, 3600 and 4000
mm) and 1500 mm deep.
FUNCTIONAL AND
CONSTRUCTION
FEATURES
Constructed entirely in 304 AISI
stainless steel.
Two separate air circuits
(extraction and intake) to reduce the
quantity of treated air released in the
environment.
Rear exhaust with filters and front
air intake through a narrow slot sized
to obtain the correct induction effect.
Perforated panel inside the intake
circuit to guarantee a perfect and
uniform air distribution.
Completely insulated intake area
to avoid external condensation.
Labyrinth filters in 304 AISI
stainless steel easily removable for
cleaning. Labyrinth filters guarantee
constant filtration to avoid clogging
and protect against fire.
Perimetral gutter with drain hole to
transfer grease into a 304 AISI
container.
External panels with upturned
edges to avoid injuries.
The outlet holes are sized in order
to minimize drops in pressure.
Pressure gauging for perfect
calibration.
Built-in lighting with protective
screen.
Available, as optional accessory,
an air intake Plenum, which is
insulated to avoid condensation.
Heating and air conditioning costs
reduced up to 60%.