Zanussi MCV1416BT Ventilation Hood User Manual


 
ZANUSSI
P R O F E S S I O N A L
430 AISI CENTRAL TYPE HOODS
MASTER - MV line - 1400 mm
430 S/S LABYRINTH FILTER H=500 MM 4 6 6 8 10 10 12 14
304 S/S BLIND PANEL 400X500H MM 2 2 2 2 2
INCLUDED ACCESSORIES
Supply voltage 220/240 V, 1N,
50/60
220/240 V, 1N,
50/60
220/240 V, 1N,
50/60
220/240 V, 1N,
50/60
220/240 V, 1N,
50/60
220/240 V, 1N,
50/60
220/240 V, 1N,
50/60
220/240 V, 1N,
50/60
Net weight - kg. 39 45 52 69 76 82 89 96
installed-electric 0.55 0.55 1.1 1.1 1.1 1.1 1.1 1.1
Power - kW
Built-in fan - power W 550 550 550 550 550 550 550 550
Air Capacity - mc/h 3800 3800 7600 7600 7600 7600 7600 7600
height 500 500 500 500 500 500 500 500
depth 1400 1400 1400 1400 1400 1400 1400 1400
width 1200 1600 2000 2400 2800 3200 3600 4000
External dimensions - mm
MCV1412BT
642137
MCV1416BT
642138
MCV1420BT
642139
MCV1424BT
642140
MCV1428BT
642141
MCV1432BT
642142
MCV1436BT
642143
MCV1440BT
642144
CHARACTERISTICS MODELS
TECHNICAL DATA
RANGE
COMPOSITION
A range of central hoods used for
snack applications and on the N700
and N900 Series cooking units. Their
particular profile and the limited
installation height makes them
suitable for use in places with low
ceilings. The range consists of
hoods with 8 different lengths (1200,
1600, 2000, 2400, 2800, 3200, 3600
and 4000 mm) and a depth of 1400
mm.
FUNCTIONAL AND
CONSTRUCTION
FEATURES
Constructed entirely in 430 AISI
stainless steel.
Labyrinth filters in 430 AISI
stainless steel easily removable for
cleaning. Labyrinth filters guarantee
constant filtration to avoid clogging
and protect against fire.
Powerful internal fan(s) 550 W.
Central drain pipe with drain hole
to transfer grease into a 304 AISI
container.
External panels with upturned
edges to avoid injuries.
Blind panels in 304 AISI stainless
steel for a correct exhaustion.
The outlet holes are sized in order
to minimize drops in pressure.
Pressure gauging for perfect
calibration.
Condensate collection tray in 304
AISI stainless steel.
Eyebolts and screw anchors for
ceiling installation.
Prearranged for installation of
lighting.