as above, powder not emptying properly and cleaning properly only recent. Machine a few months old

Asked by Fiona on 07/01/2008 1  Answer

ManualsOnline posted an answer 15 years, 11 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
4 Mine too displayed the same problem - not heating, therefore not cleaning or drying properly (door still cold 20 minutes into cycle). I've found that there is a common (yet not often talked about) issue with a point on the controllers circuit board. If you remove the controller (simple to get at), remove the circuit board from the controller and flip it over you will see a 'burnt' solder joint on one of the legs to a black box component - resolder that joint and all should be well. Don't pause or open the door during a cycle as this seems to cause the joint to blow.