We had a 1 hr power outage two days ago, then the next day, heard beeping followed by relay clicks, and noticed not freezing well. Yesterday, I made sure coils and fan in bottom back of unit are clean and running good. Then I shut power off for a few minutes. The beeping stopped, but the compressor is still almost always running, not getting cool, relay clicking every minute or two. What else can I check to troubleshoot? (I plan on opening up the panel inside today to see if the inside blower is operating. I am handy with repairs, but I dont have a troubleshooting manual. I do have schmatic diag though.

Asked by mark on 01/23/2009 2  Answers

ManualsOnline posted an answer 15 years, 8 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
5 A new start-overload relay has fixed the problem. This is the modules that connect directly to the compressor motor's 3 prong connector. I used WP kit part# 8201799