AEG 2073-4 GS Freezer User Manual


 
39
Door reversibility
Unplug the freezer before performing the following
operations:
Remove the ventilation grill (D).
Remove the lower hinge (E) by loosening the two
fastening screws.
Remove the door by sliding it out of the upper pin (A-
Fig. 3).
Unscrew the pin and the washer (A+B-Fig. 3) and
refit them on the opposite side.
Refit the door.
Refit the lower hinge (E-Fig. 2) on the opposite side
by means of the two screws that have been previously
removed.
Remove the plug (F) from the ventilation grill (D) and
replace it on the opposite side.
Refit the ventilation grill.
Remove the handle and refit it on the opposite side
(Fig. 4).
Unscrew the handle. Refit it on the opposite side after
having pierced the plugs with a punch. Cover the
holes left open with the plugs contained in the
documentation pack.
If, after having reversed the door, it is not in line with
the unit, the top hinge can be adjusted.
To do this, use a 10 mm spanner as shown in Figure 3;
slacken the nut, align the door by pushing it to the left
or right, then re-tighten the nut.
Attention
After having reversed the opening direction of the
door check that all the screws are properly
tightened and that the magnetic seal adheres to the
cabinet. If the ambient temperature is cold (i.e. in
Winter), the gasket may not fit perfectly to the
cabinet. In that case, wait for the natural fitting of the
gasket or accelerate this process by heating up the
part involved with a normal hairdrier.
Fig. 2
Fig. 3
Fig. 4
E
F
D
PR185
F
F
F
C
B
A
D427
PR228