AEG 3009VNMM Double Oven User Manual


 
6
DO NOT LIFT COOKER BY THE FRONT DOOR AS THIS WILL DAMAGE THE OVEN
The operations indicated below must be followed by qualified personnel, in conformity with the
regulations in force.
The supplier refuses all responsibility for damages to person or property, resulting from
the failure to comply with such provisions.
The appliance is designed to be used near heat resistant pieces of furniture or kitchen cabinetry
only.
ELECTRICAL CONNECTIONS (FIG.7)
Before carrying out electrical connection, be sure that the characteristics of the electrical system
meet the specifications located at the bottom of the cooktop and the electrical system is provided
with effective ground in compliance with the regulations and provision of the law in your country.
The ground is required in all circumstances.
If you wish a direct connection to the line, it is necessary to use a single pole switch, with a
minimum opening between the contacts of 3 mm. suitable for the purpose and in conformity with
the rules in your country (the yellow/green ground cable should not be interrupted by the switch).
ATTENTION
Disregard of this precaution could cause the incorrect operation of the touch control system of the
cooktop and effect the product warranty provisions.
WARNING:
All aspects of the installation must conform with the requirement of the Standards North
America (within North America) wiring rules, as well as your local electrical and building
codes and regulations, and any other applicable requirements and conditions of your
local power supply authority. Your appliance must be properly installed and grounded by
a qualified and licensed technician.
240 Volt 60Hz 30AMP single/40AMP double service
Incorrect installation of the appliance, resulting from the kitchen maker not following the detailed
installation specifications, can affect the appliance performance
CONNECTION TO THE GAS SUPPLY: CURRENT INSTALLATION STANDARDS
The cooker should be connected according to local regulations,
using either a rigid or flexible connections.
a) For building in: Use a continuous flexible stainless steel pipe, as
per current installation standards, which can be extended to a
maximum of 2000 mm.; the ends of the pipe must be fitted with
an ISO 228/1coupling and gasket or an ISO 7/1 threaded
coupling with mechanical gasket.