35
H
F
D
PR18
F
F
F
E
E
G
Rehingeing the door
The side at which the door opens can
be changed from the right side (fac-
tory adjustment) to the left side, if
the installation site requires.
Warning! When changing the side at
which the door opens, the appliance
may not be connected to the mains.
Remove plug from the mains befo-
rehand.
Procced as follow:
1. Remove the clip-in ventilation grille
(D).
2. Remove the bottom hinge (E) by
unscrewing the fixing screws.
3. Slide the bottom door off the centre
hinge (H).
4. Remove the centre hinge and slide
the top door off pin (G); unscrew pin
(G) and refit it on the opposite side.
5. Remove the two plugs, to reveal the
holes for the hinge pivots, and
remount them on the other side.
6. Refit the top door and the centre
hinge (H) on the opposite side.
7. Refit the bottom door.
8. Using a 10 mm spanner, unscrew
the hinge pin (E) and reassemble it
on the opposite side of the hinge;
9. Refit bottom hinge (E) on the oppo-
site side, using the screws previously
removed.
10. Remove blanking cover (F) from ven-
tilation grille (D) by pushing it in the
direction of the arrow and refit it on
the opposite side.
11. Refit ventilation grille (D), clipping it
into place.