6. After approximately 20 minutes the drain hose at the rear of the cabinet starts to dis-
charge water into the drip tray.
7. To prevent the water overflowing from
the drip tray dry with a sponge.
8. The defrosting process ends when the
water stops dripping. It may take several
hours if the problem started long before.
9. Move the appliance to the original posi-
tion.
10. Clean and dry the inside of the appli-
ance.
11. Connect the mains plug into the mains
socket.
12. Switch on the appliance.
TECHNICAL DATA
Dimension of the recess
Height 1600 mm
Width 600 mm
Depth 630 mm
Rising Time 21 h
Voltage 230-240 V
Frequency 50 Hz
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.
INSTALLATION
WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the appli-
ance before installing the appliance.
Location
The appliance should be installed well away from sources of heat such as radiators, boilers,
direct sunlight etc. Ensure that air can circulate freely around the back of the cabinet. To
ensure best performance, if the appliance is positioned below an overhanging wall unit, the
minimum distance between the top of the cabinet and the wall unit must be at least 100
mm . Ideally, however, the appliance should not be positioned below overhanging wall
14 Technical data