TECHNICAL DATA
A92860GNB0 A92860GNX0
Dimension
Height 1810 mm 1810 mm
Width 595 mm 595 mm
Depth 650 mm 650 mm
Voltage 230 V 230 V
Frequency 50 Hz 50 Hz
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.
Water pressure range
The water pressure must be at least 1 bar (100kPa) Consult your installer if water pressure is
less than 1 bar.
Highest allowed water pressure 10 bar (1000kPa) If water pressure exceeds 10 bar a re-
duction valve must be fitted (available
from your specialist shop).
Do not connect the appliance in spaces where ambient temperature can decrease to be-
low freezing.
The appliance may only be connected to drinking water supplies.
The appliance may only be connected to cold water supplies.
INSTALLATION
WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the appli-
ance before installing the appliance.
Positioning
Install this appliance at a location where the ambient temperature corresponds to the cli-
mate class indicated on the rating plate of the appliance:
Climate class Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
Location
To ensure best performance, if the appliance is positioned below an overhanging wall unit,
the minimum distance between the top of the cabinet and the wall unit must be at least 40
Technical data