AEG CHDF 6260 Ventilation Hood User Manual


 
75
Removing the hood from the wall unit
If, for technical reasons (extraction version/recirculation version
conversion) the extractor hood has to be removed from the wall unit,
proceed as follows:
Fully withdraw the visor and remove the grease filter.
Loosen the 4 or 6 mounting screws of the hood (wall unit mounting).
To loosen both mounting claws (installation aids), place a max 3
mm dia. Phillips screw-driver in the spring opening and
simultaneously press the springs inwards (towards the appliance
housing). Fig. 14.
Important: Hold the hood firmly!
Adjusting the extractor part (E - Fig. 1) - Fig. 15
On wall units with a body depth of 275 mm to 335 mm, the visor depth
can be adjusted as follows:
Remove both grease filters.
Loosen the screws on both end-stop brackets and set the visor
depth (min. 275 mm, max. 335 mm).
Refit the screws.
Refit the grease filters.
Fig. 14