AEG E4100-1 Oven User Manual


 
Installation Instructions
54
Installation Instructions
1
Important: The new appliance is only to be installed and connected up
by an approved installer.
Please observe this instruction, otherwise the warranty will not cover
any damage that may occur.
1 Safety Instructions for the Installer
A device must be provided in the electrical installation which allows
the appliance to be disconnected from the mains at all poles with a
contact opening width of at least 3mm.
Suitable isolation devices are e.g. circuit breakers, fuses (screw-type
fuses are to be removed from the holder), earth leakage trips and
contactors.
Anti-shock protection must be guaranteed by the installation.
The unit in which the appliance is fitted must satisfy the require-
ments of DIN 68930 in respect of stability.
Built-in ovens and cooking surfaces are fitted with special connector
systems. They may only be combined with appliances with a matching
system.