AEG HK654200IB Cooktop User Manual


 
sensor field function
10
It activates and deactivates STOP+GO
Heat setting displays
Display Description
The cooking zone is deactivated.
-
The cooking zone operates.
The function operates.
The Automatic Heat Up function operates.
Power function operates.
+ digit
There is a malfunction.
/ /
OptiHeat Control (3 step Residual heat indicator) : continue cook /
stay warm / residual heat.
Lock/The Child Safety functions operates.
Not correct cookware or too small or no cookware on the cooking
zone.
The Automatic Switch Off function operates.
OptiHeat Control (3 step Residual heat indicator)
WARNING!
\ \ The risk of burns from residual heat!
OptiHeat Control shows the level of the residual heat. The induction cooking zones make
the heat necessary for cooking directly in the bottom of the cookware. The glass ceramic is
hot from the heat of the cookware.
OPERATING INSTRUCTIONS
Activation and deactivation
Touch for 1 second to activate or deactivate the appliance.
Automatic Switch Off
The function stops the hob automatically if:
All cooking zones are deactivated.
You do not set the heat setting after you activate the appliance.
You spill something or put something on the control panel for more than 10 seconds, (a
pan, a cloth, etc.). The sound operates some time and the appliance deactivates. Remove
the object or clean the control panel.
The appliance become too hot (e.g. when, a saucepan boils dry). Before you use the hob
again, the cooking zone must be cool.
Operating instructions
9