CUL/HVI
7
7
/
8"
4"
10
7
/
8"
9
3
/
8"
11"
13
3
/
4"
SPECIFICATIONS
EXHAUST FANS
AK1 1 0LS
110 CFM/1.5 SONES @ 0.10" wg. • 90 CFM/1.5 SONES @ 0.25 wg.
HVI CERTIFIED 120 Volts, 0.30 amps, 60 hz.
• Grill
White, polymeric grill secured in place with torsion springs;
easily removed if necessary, dimensions - 11" x 13
3
/
4
".
• Blower Wheel
Balanced polymeric dual inlet blower wheel 5
13
/32
" dia. x 4"
depth, 30 paddles, secured in place using 8M hex nut.
• Motor
Enclosed 4 pole electronically balanced permanently split
capacitor motor (PSC);
life time lubrication, suitable for
continuous operation
. Motor bearings - ball. Rated 115/120 volts,
60 Hz, 0.30 amps.
• Fan Housing
23 gauge galvanized steel housing, fully sealed.
Overall dimensions 10
7
/
8
" x 9
3
/
8
" x 7
7
/
8
".
• Duct Collar
4" round, zinc plated metal collar adapter. 4" spring loaded
aluminum backdraft damper.
• Ventilating Area
For bathrooms up to 110 sq. ft. For other rooms up to 135 sq. ft.
• Electrical Connections
1
/
2
" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048
Updated 6-06Specifications subject to change without notice.
• Unit Mounting
The housing will mount in ceilings with at least 8" of clearance
and through drywall thickness up to
3
/
4
", with a rough-in opening
of 11
1
/
8
" x 9
5
/
8
". Rated for ceilings insulated to R-40. The housing
will mount either between 16" or 24" on center joists, using the
4 supplied housing mounting rails. The housing mounting rails
can be adapted for overhead mounting (hardware not provided).
• Single Pack Shipping Info
Box Dim: 14
1
/
8
" x 11
5
/
8
" x 9
5
/
8
"
UPC: 0-8316221121-7
Shipping Weight: 11.5 lbs.
CUS
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
PERFORMANCE
HVI Sones Fan Speed Power
Static Pressure (inches of w.g.) @ .1 SP RPM Watts
0 0.05 0.1 0.2 0.25 0.3 0.35 0.4
Air Flow - CFM
119 115 110 99 90 75 65 48 1.5 1125 28