Air King B500 Ventilation Hood User Manual


 
3. Using 8 of the included 8-32 screws and washers, mount the
blower in place and tighten all screws. Confirm that the
blower is securely seated in place and there are no air gaps
around the blower gasket.
4. Plug the 3 wire quick connect cord from the blower into the
receptacle on the range hood canopy. Plug the 4 wire quick
connect cord from the blower into the one end of the wiring
harness then connect the other end of the wiring harness to
the receptacle in the range hood canopy. These cords will
only fit into the receptacles one way (Figure 3).
5. Reinstall the rear bottom plate by fitting the back edge of the
plate into the channel located on the back of the hood and
reinstalling the two screws and washers removed in
Step 1
(Figure 5).
SECTION 4
Finishing the Installation
1. Install the included fuse into the electrical panel by turning
the fuse cap counter clockwise and pulling out. Insert the
included 1/4" x 1-1/4" time delay fuse in the holder and
reinstall into the panel (Figure 6).
NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4"
Bussman MDA-3 or equivalent 3 amp, 250V ceramic, time delay
fuse only.
2. Refer to the hood instruction manual to complete the
installation, for maintenance, and before restoring power.
3. The blower is covered under the range hood’s warranty.
Fuse
Figure 6
Cap
Channel
Figure 5
Screw
Bottom Plate
Washer
www.airkinglimited.com
111597002 Rev. A 9-07
3 of 12