4. Tighten all connections securely. Turn on gas and
check all pipe connections (internal & external)
for gas leaks with a non-corrosive leak detection
fluid.
NOTE: The dryer and its appliance main gas valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures in excess of 1/2 psi (3.45 kPa).
Refer to Step 12 (Check Heat Source).
L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft
3
(93.1 MJ/m
3
) service must be supplied at 10 ± 1.5 inch
water column pressure.
For proper operation at altitudes above 3000 feet
(915 m) the L.P. gas valve spud orifice size must be
reduced to ensure complete combustion. Refer to
Table 2.
NOTE: DO NOT connect the dryer to L.P. Gas
Service without converting the gas valve. Install
L.P. Gas Conversion Kit 649P3, available at extra
cost.
Step 6: (Electric Dryer Only) Connect
Electrical Plug
NOTE: Model LTSA7A*N2989 - A single electrical
connection serves both washer and dryer.
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz,
3 or 4 wire electrical supply. Refer to serial plate for
specific electrical requirements.
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
L.P. Altitude Adjustments
Altitude Orifice Size
Part No.
feet m No. inches mm
3000 915 55 0.0520 1.32 58755
8000 2440 56 0.0465 1.18 503786
Table 2
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer’s responsibility to have the wiring
and fuses installed by a qualified electrician
to make sure adequate electrical power is
available to the dryer.
W521
WARNING