Alto-Shaam 1000-UP Food Warmer User Manual


 
holding cabinetsinstallation/operation/service manual - pg. 14
ELECTRICAL
INSTALLATION
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
CAUTION
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
500-S
voltage phase cycle/hz amps kW cord & plug
120 1 60 8.4 1.0 NeMa 5-15p,
15a-125v plug
208 1 60 3.7 .76 NeMa 6-15p,
240 1 60 4.2 1.0
15a-250v plug
(usa only)
230 1 50/60 4.1 .95 cee 7/7,
220-230v plug
750-S
voltage phase cycle/hz amps kW cord & plug
120 1 60 9.0 1.1 NeMa 5-15p,
15a-125v plug
208 1 60 3.9 .81 NeMa 6-15p,
240 1 60 4.5 1.1
15a-250v plug
(usa only)
230 1 50/60 4.3 1.0 cee 7/7,
220-230v plug
1000-UP
voltage phase cycle/hz amps kW cord & plug
120 1 60 16.0 1.9 NeMa 5-20p,
20a-125v plug
208 1 60 7.0 1.4 NeMa 6-15p,
240 1 60 8.0 1.9
15a-250v plug
(
Usa only)
230 1 50/60 7.7 1.8 cee 7/7,
220-230v plug
1000-S
voltage phase cycle/hz amps kW cord & plug
120 1 60 8.0 .96 NeMa 5-15p,
15a-125v plug
208 1 60 3.5 .72 NeMa 6-15p,
240 1 60 4.0 .96
15a-250v plug
(usa only)
230 1 50/60 3.9 .88 cee 7/7,
220-230v plug
230
208 - 240
120
1200-S
voltage phase cycle/hz amps kw cord & plug
120 1 60 8.0 .96 NeMa 5-15p,
15a-125v plug
208 1 60 3.5 .72 NeMa 6-15p,
240 1 60 4.0 .96
15a-250v plug
(Usa only)
208 1 60 6.9 1.4
no cord
240 1 60 8.0 1.9
or plug
230
1000W 1 50/60 3.9 .88 cee 7/7,
230
2000W 1 50/60 7.7 1.8 220-230v plug
1000W
2000W
230
208 - 240
120
2000W
4000W
1200-UP
voltage phase cycle/hz amps kw cord & plug
120 1 60 16.0 1.9 NeMa 5-20p,
20a-125v plug
208 1 60 7.0 1.4 NeMa 6-15p,
240 1 60 8.0 1.9
15a-250v plug
(Usa only)
208 1 60 14.0 2.9
no cord
240 1 60 16.0 3.8
or plug
230
2000W 1 50/60 7.7 1.8 cee 7/7,
230
4000W 1 50/60 15.4 3.5 220-230v plug
300-S
voltage phase cycle/hz amps kW cord & plug
120 1 60 6.7 .80 NeMa 5-20p
20a-125v plug
230 1 50/60 3.9 .80 cee 7/7
220-230v plug
Wire diagrams are located inside the bonnet of the unit.