Alto-Shaam 1200-TH/III Oven User Manual


 
pg. 14 TH/III InsTallaTIon/operaTIon/servIce manual
ELECTRICAL
INSTALLATION
300-TH/III
voltage phase cycle/hz amps kW cord & plug
120 1 60 6.7 .80 NeMa 5-15p
15a-125v plug
230 1 50/60 3.5 .80 cee 7/7
220-230v plug
Wire diagrams are located inside the bonnet of the unit.
ELECTRICAL - 1200-TH/III
voltage phase cycle/hz amps kW cord & plug
208-240 (agcy) 1 60 30 7.2
no cord
at 208 1 60 28.9 6.0
or plug
at
240 1 60 33.3 8.0
230
(agcy) 1 50 28.7 6.6 no cord or plug
ELECTRICAL - 500-TH/III
voltage phase cycle/hz amps kW cord & plug
120 1 60 16.0 1.92 NeMa 5-20p
20a-125v plug
208-240 (agcy) 1 60 11.2 2.70
cord,
at 208 1 60 10.6 2.20
no plug
at 240 1 60 12.2 2.93
230 1 50 12.0 2.75 cee 7/7
220-230v plug
ELECTRICAL - 750-TH/III
voltage phase cycle/hz amps kW cord & plug
208-240 (agcy) 1 60 15.8 3.80
cord,
at 208 1 60 14.6 3.04
no plug
at 240 1 60 16.9 4.05
230 (agcy) 1 50 14.3 3.3 cee 7/7
220-230v plug
ELECTRICAL - 1000-TH/III
voltage phase cycle/hz amps kW cord & plug
208-240 (agcy) 1 60 15.8 3.8
cord,
at 208 1 60 14.4 3.0
no plug
at 240 1 60 16.7 4.0
230 1 50 14.3 3.3
cee 7/7
220-230v plug
ELECTRICAL - 1200-TH/III - UK ONLY
voltage phase cycle/hz amps kW cord & plug
230 (agcy) 1 50 21.3 4.9 no cord or plug