MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 6
1. An identification tag is permanently mounted on
the cabinet.
2. Plug cabinet into a properly grounded receptacle
ONLY, positioning the unit so the power supply
cord is easily accessible in case of an emergency.
Arcing will occur when connecting or
disconnecting the unit unless all controls are in
the “OFF” position.
3. If necessary, a proper receptacle or outlet
configuration as required for this unit, must be
installed by a licensed electrician in accordance
with applicable, local electrical codes.
CAUTION
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
ELECTRICAL
INSTALLATION
Wire diagrams are located inside the bonnet of the unit.
ELECTRICAL
voltage phase cycle/hz amps kW
120 1 60 5.3 0.64 nema 5-15p
15a, 125V plug
208-240 1 60 2.7 0.64
nema 6-15p
15a, 250V plug
230 1 50/60 2.6 0.59
cee 7/7,
220-230V plug
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
NOTE: Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.