Alto-Shaam AR-7H MANUAL CONTROL Oven User Manual


 
AR-7H Hot Holding Rotisserie Companion Operation & Care Manual 5
I N S TA L L AT I O N
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the OFF position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
After wiring and power connection has been
completed, turn the main power switch to the ON
position. The main power switch can be left ON
for daily use, but should be turned OFF when
c
leaning or performing maintenance or repairs to
the rotisserie.
REGARDING INTERNATIONAL
STANDARD UNITS:
If the unit is not equipped with flexible cord
with plug, an all-pole country approved
disconnection device which has a contact
separation of at least 3mm in all poles must be
incorporated in the fixed wiring for disconnection.
When using a cord without a plug, the
green/yellow conductor shall be connected to the
terminal which is marked with the ground symbol.
If a plug is used, the socket outlet must be easily
accessible. If the power cord needs replacement,
use a similar one obtained from the distributor.
For 230V units:
To prevent an electrical shock
hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts to
provide sufficient protection against potential
difference. The terminal is marked with the
following symbol.
E L E C T R I C A L CO N N E C T I O N
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS KW
120 1 50/60 15.0 1.8
NEMA 5-20P
20A, 125V
PLUG
AT 208 1 50/60 8.5 1.8
NEMA 6-15P
15A, 250V
PLUG
AT 240 1 50/60 9.5 2.3
NEMA 6-15P
15A, 250V
PLUG
230 3 50/60 9.0 2.1
CEE 7/7
220-230V
PLUG
208-240V