Electric Fryer Operation & Care Manual • 10
INSTALLATION
1. Refer to the nameplate on the FRONT of the fryer. Verify the electrical service power. Voltage and
phase must match the nameplate specifications and available electrical service amperage must meet or
exceed the specifications listed.
Wiregauge,insulationtypeandtemperaturerating,aswellastype,sizeandconstruction
of conduit, must meet or exceed applicable specifications of local codes and of the National
Electrical Code.
2. The fryer is shipped from the factory wired for 3-phase electrical service. This fryer is not
approved for conversion to single phase. Converting to single phase will void the
warranty and invalidate the ETL certification.
IMPORTANT: Field wiring must be routed and secured away from the frypot, tubing, and filter pump
and motor. Field wiring must allow access to the rear of the fryer for cleaning and for
.
Warning!
440-480V - 3 Phase Only
The pump motor should rotate clockwise when viewed
from the rear of the fryer.
To change rotation, swap any two lines of 3 Phase incoming power.
ELECTRICAL INSTALLATION
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
DANGER
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.