Alto-Shaam HFT2SYS-500 Food Warmer User Manual


 
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 9.
ELECTRICAL CONNECTION
INSTALLATION
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “off” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
REGARDING INTERNATIONAL
STANDARD UNITS:
If the unit is not equipped with flexible cord with
plug, an all-pole country approved disconnection
device which has a contact separation of at least
3mm in all poles must be incorporated in the fixed
wiring for disconnection. When using a cord
without a plug, the green/yellow conductor shall
be connected to the terminal which is marked with
the ground symbol. If a plug is used, the socket
outlet must be easily accessible. If the power cord
needs replacement, use a similar one obtained
from the distributor.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
Wire diagrams are included in the literature
package supplied with the unit.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
ELECTRICAL - HFT2-300
voltage phase cycle/hz amps kW corD & plug
208-240 (agcy) 1 60 13.6 3.3 NEMA 6-15P
at 208 1 60 11.8 2.5 15A - 250V Plug
at 240 1 60 13.6 3.3
230 1 50 13.0 3.0
cee 7/7,
220-230v plug
ELECTRICAL - HFT2-400
voltage phase cycle/hz amps kW corD & plug
208-240 (agcy) 1 60 13.7 3.3 NEMA 6-20P
at 208 1 60 11.9 2.5 20A - 250V Plug
at 240 1 60 13.7 3.3
230 1 50 13.1 3.0
cee 7/7,
220-230v plug
ELECTRICAL - HFT2-500
voltage phase cycle/hz amps kW corD & plug
208-240 (agcy) 1 60 15.7 3.8 NEMA 6-20P
at 208 1 60 13.6 2.8 20A - 250V Plug
at 240 1 60 15.7 3.8
230 1 50 15.0 3.5
cee 7/7,
220-230v plug