QUICKCHILLER • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 18.
SUB TITLE
TITLE
caution
ADEQUATE SPACING MUST
BE ALLOWED BETWEEN PANS
FOR PROPER AIR CIRCULATION
FOR BOTH PROCESSING AND
SUBSEQUENT HOLDING.
ADVANCED OPERATION
OPERATION
The date and time will appear in the display when
the unit is off. When the unit is turned on, the
screen will read: “SELECT MODE OR PRESS START TO
SELECT PRESET”
To initiate any Quickchiller operating mode,
power must initially start from the off position
or an operating mode must be halted by pressing
the START/STOP key so that the SELECTION SCREEN
appears on the display.
NOTE: With the exception of the QC2-3 counter top
Quickchiller model, the Alto-Shaam name on
the control panel will illuminate whenever
the power key is pressed to the on position.
HOLD TEMP
Starting from the off position, press the
power key on. The SELECTION SCREEN will
appear on the display. The compressor will
become energized and will begin to operate
if required by the sensors.
Press the HOLD TEMP key. The display will
indicate the default hold temperature
(changeable in User Settings).
To change the displayed temperature, press the
up5or down6arrow key to increase or decrease
the temperature display within the refrigeration
storage parameters of the mode -5°F to
+40°F (-21°C to +4°C).
note: THE MOdIfIEd HOLdINg TEMPERATURE SET-POINT IS NOT
SAVEd. THE dEfAULT HOLd TEMPERATURE CAN bE CHANgEd
UNdER USER SETTINgS.
Press the START/STOP key to begin
operation of the Quickchiller in the
mode.
The display will indicate:
The length of time the chiller is
operating in the mode.
The temperature set by the operator.
The air temperature inside the
chiller compartment.
The temperature of all food probes.
WHEN IN THE HOLD TEMP MODE AFTER
A CHILL MODE:
Press the UP 5arrow key to display the maximum
sensor temperature achieved during the completed
chill cycle. Press the DOWN 6 arrow key to display
the minimum sensor temperature achieved during
the completed chill cycle. Press the right4or
left3arrow key to display the Probe Done Time.
caution
NEVER STACK PANS DIRECTLY
ON TOP OF EACH OTHER.
STACKED PANS WILL RESTRICT
AIR FLOW AND INCREASE CHILL
PROCESSING TIME.