Alto-Shaam QC2-40 Freezer User Manual


 
QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 20.
SUB TITLE
TITLE
chanGinG user settinGs
Starting from the off position, press the power
key on. The Alto-Shaam name will illuminate
and the SELECTION SCREEN will appear on the
display. The compressor will become energized
and will begin to operate if required by the
sensors.
Press the PROGRAM key. The display will
indicate the User Settings each time the 
key is pressed.
Press the up 5or down6arrow keys to select the
desired User Setting. Press the right4or left3arrow
keys to change the value.
Press the PROGRAM key to save settings and
return to the SELECTION SCREEN.
proGramminG user settinGs
1. START MANUAL DEFROST
Select Start Manual Defrost and press the START/
STOP key to initiate a manual defrost cycle. The
defrost cycle will complete operation when the
temperature of the coil or coils reach set-point
values or after a user set period has been
reached, whichever occurs first.
2. DEFROST FREQUENCY
The display will indicate the length of time
necessary to accrue before the Fan Timer triggers an
automatic defrost cycle. The length of time can be
adjusted by pressing the right4or left3arrow keys
to increase or decrease automatic defrost cycle time
(4-10 hours).
3. LANGUAGE
The display will indicate the currently selected
language. Press the right4or left3arrow key to
select English, Spanish, or French as the language of
choice.
4. DATE
The display will indicate , and 
(YYYY/MM/DD). Press the up5or
down6 arrow key to select the date, time, and day,
and the right4or left3arrow key to increase or
decrease the numbers as required.
5. TIME
The display will indicate the current  of day
(HH:MM). Press the up5or down6arrow key
to select the hours or minutes and the right4or
left3arrow key to increase or decrease the numbers
as required.
6. °F/°C - Fahrenheit/Celsius
The display will indicate a choice between 
and  for Quickchiller temperature display
readings. Press the right4or left3arrow key to
toggle the setting.
7. HOLD DEFAULT
The display will indicate the default 
temperature. Press the right4or left3arrow key to
increase or decrease the default holding temperature
between a range of -5°F to +40°F (-21°C to +4°C).
ADVANCED OPERATION
OPERATION
USER SETTINGS
1.
Start Manual Defrost
8.
HACCP Download
2.
Defrost Frequency
9.
Probe Verification
3.
Language
10.
Preset Lock
4.
Date - YYYY/MM/DD
11.
Chill Mode Lock
5.
Time - HH:MM
12.
Defrost Time (Minutes)
6.
°F/°C - Fahrenheit/Celsius
13.
Drip Time (Minutes)
7.
Hold Default
14.
Factory Settings
ADVANCED OPERATION – USER SETTINGS
OPERATION