STEP 5: INSTALL THE MOUNTING PLATE
THE OVEN MUST BE CONNECTED TO AT
LEAST ONE WALL STUD.
1. Draw a vertical line on the wall at the center of the 30″ wide
space.
Use the mounting plate as the template for the rear wall.
Place the mounting plate on the wall, making sure that the
tabs are against the bottom of the cabinet. Line up the
notch and center line on the mounting plate to the center
line on the wall.
2. While holding the mounting plate with one hand, draw
circles on the wall at holes A, B, C and D. Four holes must
be used for mounting. If the holes are not used, the
installation will not be secure. Installer must use these
holes for proper installation. Use toggle bolts through these
holes unless one of them lines up with a stud. Use a wood
screw for studs.
NOTE: Draw a fifth circle inside area E, through one of the
bottom holes to match the location of a stud.
For wall-vented: The oven requires a rear wall cutout opening
for the rear wall duct and the exhaust adaptor must be
attached to the mounting plate. See the next page on how to
prepare the rear wall cutout opening and the exhaust
adaptor/mounting plate for wall-vented.
3. Drill holes on the circles. If there is a stud, drill a 3 / 16″
hole for lag screws. If there is no stud, drill a
3/4″ hole for toggle bolts. Make sure to use at least 1 lag
screw in a stud, and 4 toggle bolts in the drywall or the
plaster.
4. Attach the plate to the wall. To use spring toggle heads
bolts: Remove the toggle wings from the bolts. Insert the
bolts into the mounting plate and replace the spring toggle
heads to 3 / 4″ past the bolt ends. Insert the spring toggle
heads into the holes in the wall to mount the bracket. You
may pull forward on the bracket to help in tightening the
toggle bolts. Tighten all bolts.
INSTALLATION
18
Center Line
A
C
B
3/16" Hole on Studs
3/4" Hole on Drywall Only
Draw
Center Line
Draw Lines
on Studs
Wall
Mounting
Plate
Space More Than Wall Thickness
Bolt
End
Toggle Bolt
Toggle Wings
For Wall-
Vented Only
Minimum 66
"
From the Floor
Support Tab Support Tab
E
Mounting
Plate
Figure 26
Figure 27