Amana ARR6202 Oven User Manual


 
Installing 4-Wire Power Cord
WARNING
To avoid the risk of severe electrical shock or death,
ground wire must be attached to frame of range, using
ground screw provided. Ground wire must not contact
any other terminal.
1. Remove rear wire cover on back of range.
2. Place strain relief (winged clamp) in cord access hole
below terminal block.
Strain relief is supplied with cord. Place wings
through hole entering from bottom.
Screw holes in clamp should be below mounting
panel.
3. Remove green ground screw (retain for use in step 8)
and unscrew brass nut on center terminal. Remove
grounding strap.
Wires from range
(Number of wires on each terminal can vary)
Center terminal II
nut
Grounding
strap
Green ground
screw
Remove Green Ground Screw
4. Place cord through strain relief.
5. Attach cord neutral (center) or white wire to center
terminal on terminal block. Secure with hex nuts
provided. See "Attach 4-wire Power Cord" illustration.
6. Attach power lead, red wire or black wire to left
terminal. Secure with hex nuts provided.
7. Attach power lead, red wire or black wire to right
terminal. Secure with hex nuts provided.
.
A
Wires from range
Number of wires on each terminal can vary)
A
)
Wires from power cord
_Power lead terminal (Connect black or red insulated wire and
secure with brass nut.)
B_eutral terminal (Connect insulated white insulated wire and
secure with brass nut.)
Attach 4-wire Power Cord
Position grounding strap down and away from
terminal block. Attach green or bare wire and
grounding strap to back of range using green ground
screw previously removed in step 3.
Wires from range
(Number of wires on each terminal can vary)
Wires from power cord
_Ground screw (Connect green insulated wire and secure with
screw.)
Position Grounding Strap
9. Firmly tighten all connections to ensure proper
electrical connection.
10. Place screw through strain relief, tighten, and replace
rearwire cover.