Amana XRSS287BW Refrigerator User Manual


 
20
Before Calling Service
OPERATION (continued)
Controls need to be adjusted. See the controls section in your Owners Manual for
assistance in how to adjust your controls.
Refrigerator is not level. See
Installation Instructions
for
details on how to level your unit
Check for internal obstructions that are keeping door from
closing properly (i.e. improperly closed drawers, ice
buckets, oversized or improperly stored containers or
foodstuffs, etc.).
Refrigerator runs too
frequently (continued)
Door is not closing properly
Check gaskets for proper seal. Clean, if necessary,
according to cleaning instructions in Owners Manual.
ICE & WATER
Water appears cloudy
Air or air bubbles in water. This is normal when first using dispenser and will
disappear with use.
Carbon dust from water filter cartridge. Initial water ejected through cartridge may contain
harmless carbon dust flushed from cartridge. Particles are
safe for consumption. Will disappear after the first few
uses.
Particles in water and/or ice
cubes.
Concentrations of minerals in water will form
particles when water becomes frozen and
melts.
Particles are not harmful and naturally occur in water
supplies.
Freezer door is not closed.
Verify that freezer door is closed. Power is removed from
the control when freezer door is opened.
Refrigerator is not plugged in. Plug in unit.
Fuse is blown, or circuit breaker needs to be
reset.
Replace any blown fuses. Check circuit breakers for any
tripped circuits.
No indicator lights are lit on
dispenser control (some
models)
Power outage has occurred. Call local power company listing to report outage.
Freezer door is not closed. Verify that freezer door is closed. Power is removed from the
control when freezer door is opened.
Controls are in lock mode.
See Dispenser control instructions.
Water tank is filling.
At initial use, there is an approximate 45-second delay in
dispensing while the internal water tank is filling.
Ice maker or ice maker-equipped unit has just
recently been installed or a large amount of ice
has just been used.
Wait 24 hours for ice production to begin and for ice maker to
restock after emptied.
Neither ice nor water is
dispensed when pads are
pushed (some models)
Water filter is clogged or needs to be changed. Change water filter.
Ice maker has just recently been installed or a
large amount of ice has just been used.
Wait 24 hours for ice production to begin and for ice maker to
restock after emptied.
Water pressure is too low. Low water pressure can cause valve to leak. Water pressure
must be between 20 to 100 pounds per square inch to function
properly. A minimum pressure of 35 pounds per square inch is
recommended for units with water filters.
Ice maker is not producing
enough ice or ice is
malformed (some models)
Water filter is clogged or needs to be changed. Change water filter.
Ice maker arm is not in correct position Confirm ice maker arm is down. See
Automatic Ice Maker
section in your Owners Manual for details.
Household water supply is not reaching water
valve
Check water connection procedure in your
Installation
Instructions
.
Water supply tubing has kinks. Turn off water supply and remove kinks. If kinks cannot be
removed, replace tubing.
Water pressure is too low. Water pressure must be between 20 to 100 pounds per square
inch to function properly. A minimum pressure of 35 pounds
per square inch is recommended for units with water filters.
Check freezer temperature. See the controls section in your Owners Manual for assistance
on how to adjust your controls. Freezer must be between 0 to
2°F (-18 to 17°C) to produce ice.
Ice maker is not producing
ice (some models)
Ice bin is not installed properly See ice bin section for proper installation and alignment.