American Panel AP120BC1000-3 Freezer User Manual


 
AP120BC1000-3/ AP120BCF1300-3 Manual
26
zz. To change the time, press or then
press
.
04:00 Blinks
aaa. To change the temperature, press or
then press
.
-4 Blinks
bbb. To change the temperature, press or
then press
.
3 Blinks
The display will show:
PARAM. PROGRAMMING
MANUAL SHOCK CYCLE
TOTAL TIME
H 04:00 MIN
PARAM. PROGRAMMING
MANUAL SHOCK CYCLE
HOLDING LOW TEMP.
-4 °F
A
fter about 2 seconds the display will automatically
change to:
PARAM. PROGRAMMING
MANUAL SHOCK CYCLE
PROGRAMMING COMPLETE
PARAM. PROGRAMMING
MANUAL SHOCK CYCLE
HOLDING HIGH TEMP.
3 °F
PARAM. PROGRAMMING
MANUAL MODE
CHOOSE
PROGRAMMING CYCLE
NOTE: PROGRAMMING FOR "DEFROST", "UV" & "HEAT PROBE" WILL BE THE SAME IN
MANUAL MODE AS IT IS IN AUTOMATIC MODE (see pages 20-22).