PROBLEM CAUSE REMEDY
Liquid shortening does
not reach the desired
temperature for frying.
(Continued)
3. Loose knob on thermostat; or thermostat
requires calibration (temperature setting dif-
fers by about 10°F from measured shorten-
ing temperature).
(Continued)
4. Thermostat setting is more than 20°F dif-
ferent than measured shortening tempera-
ture.
3.
(Continued)
Recalibrate the thermostat by:
(a) removing the cap on the
thermostat control knob; (b)
loosening the center brass hex
nut portion of the knob; (c) turn
the pointer portion of the knob to
the measured temperature value
of the thermostat settings.
Tighten the brass hex nut to lock
the adjustment. Replace the
cap on the knob.
4. Check the thermostat setting
against an accurate measure of
the shortening temperature. If
the temperature difference is
greater than 20°F, the thermo-
stat can
possibly be recali-
brated.
Recalibrate the thermostat by:
(a) removing the cap on the
thermostat control knob; (b)
loosening the center brass hex
nut portion of the knob; (c) turn
the pointer portion of the knob
to the measured temperature.
Tighten the brass hex nut to lock
the adjustment. Replace the
cap on the knob.
If this calibration is unsuccess-
ful, the thermostat has failed and
must be replaced.
Basket does not lower,
when the timer control
pushbutton is pressed
after the timer control
knob is set to a time
value.
1. Electric power circuit breaker not
switched ON.
2. Electric power cord not plugged into its
receptacle.
3. POWER Switch not switched ON.
4. Loosened wiring connections.
5. Timer has failed.
1. Switch the circuit breaker to
ON.
2. Plug in the power cord.
3. Switch the POWER switch ON.
4. Check wiring and tighten all
connections, especially to the
basket lifting devices (timer,
microswitch, and motor).
5. Set a time value using the timer
control knob; press the push-