Antunes, AJ 9300580 Egg Cooker User Manual


 
EGG STATION (ES-600 & ES-1200)
11
P/N 1010871 Rev. D 08/05
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel. The unit should be unplugged when servicing.
Problem Possible Cause Corrective Action
Unit fails to operate and
control panel lights fail
to signal on.
No power/low power. Make sure the Rocker Switch (power On/Off)
is ON and the power cord is locked into place.
Check the main circuit breakers.
Inoperable electrical outlet. Plug the power cord into a different outlet of
same amperage rating.
Inoperable Rocker Switch (power
On/Off) .
Contact your maintenance person or an
Authorized Service Agency.
Inoperable Power Cord.
Loose connections.
Unit fails to heat. Loose connections. Contact your maintenance person or an
Authorized Service Agency.
Inoperable Platen.
Low voltage.
Inoperable Hi-Limit Thermostat.
Inoperable Thermocouple.
Inoperable Solid State Relay.
Eggs do not cook prop-
erly.
Using refrigerated eggs and the time
selector switch is set for 2’ 00”.
Set time selector switch to 2’ 30” when using
refrigerated eggs.
Time selector switch is set for 2’ 30”
(eggs overcooked).
Set time selector switch to 2’ 00” when using
room temperature eggs.
Incorrect amount of water added to
trough in cover.
Fill trough in cover with water before starting time
cycle.
Platen Temperature is too low or too
high.
Check temperature according to the Maintenance
section of this manual..
Loose connections. Contact your Authorized Service Agency.
Unit/Table is not level Level the table and unit as necessary.
Eggs sticking to Platen. Dirty Platen. Clean Platen.
Insufficient butter being used. Refer to the Operating section of this manual.
Eggs sticking to Egg
Rings.
Insufficient butter being used. Refer to the Operating section of this manual.
Dirty Egg Rings. Do not use an abrasive scrubbing pad to clean
Egg Rings.
Inoperable Egg Ring. Replace Egg Ring.
Not signaling on “Bacon”
or “Ready”.
Inoperable indicator light or audio
signal.
Contact your maintenance person or an
Authorized Service Agency.
Inoperable Control Board.
Loose connection.
Bacon Timer is disabled Enable the Bacon Timer according to the
Operation Section of this manual
If the troubleshooting steps listed do not solve your problem, contact an A.J. Antunes Authorized Service
Agency for further assistance.