Antunes, AJ UF-420/440 Water Dispenser User Manual


 
UF SERIES WATER FILTRATION SYSTEM
6
P/N 1010827 Rev. D 04/06
SPECIFICATIONS
Electrical Ratings
CAUTION
All electrical connections must be in accordance
with local electrical codes and any other
applicable codes.
WARNING
ELECTRICAL SHOCK HAZARD.
FAILURE TO FOLLOW THE INSTRUCTIONS IN
THIS MANUAL COULD RESULT IN SERIOUS INJU-
RY OR DEATH.
Electrical ground is required on this appliance.
Do not modify the power supply cord plug. If
it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
Do not use an extension cord with this
appliance.
Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
Model Voltage Watts Hertz
UF-420 120 10 50/60
UF-440 230 10 50/60
Electrical Cord & Plug Configurations
Letter
Code*
Description Configuration
C
H
Commercial Cord
Harmonized Cord
(H)C** CEE 7/7, 16 Amp.,
250 VAC (Assembly
Only).
(C)F*** 5-15P, 15 Amp., 120
VAC., Non – Locking
(Assembly Only).
(H)K Chinese/Australian,
10 Amp., 250 VAC.
(Assembly only)
WHT
BLK
GRN
* Used in Model Designation
** Indicates that the Plug comes with a Harmonized Cord
** Indicates that the Plug comes with a Commercial Cord
Filter Cartridge Capacities
Maximum Operating Pressure 100 psig (690 kPa)
Maximum Operating Temp. 104°F (40°C)
Minimum Operating Temp. 40° F ( 4° C)
Maximum Membrane Differential Pressure 45 psi
pH Range 3-10
MWCO 100 kD
System Capacities
Series UF-420 UF-440
Liters per hour 1500 2000
Liters per minute 25 33.3
Gallons per hour 396 528
Gallons per minute 6.6 8.8