APW Wyott GF-15HLP Fryer User Manual


 
GENERAL INSTALLATION INSTRUCTIONS
Ensure gas supply and gas type, as shown onunit nameplate agree.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1-1996, the National Gas
Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2 as applicable
and in accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the
unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if
necessary to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and
water solution before operating unit.
Noncombustible clearances:
0" sides (0 mm) 0" rear (0 mm)
Do not obstructthe flowof combustion and ventilationair, under the unit by the legs or behindthe unit by the
flue.
Adequate clearance for air openings into the combustion chamber is required. Do not place objects
between the bottom of the unit and the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the burners are
removable thru the front if the gas line is disconnected.
“THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI REGISTERED
INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND
SATISFACTORY STANDARDS. THISAPPLIANCE MUSTBE INSTALLED INACCORDANCE WITH THE
GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING
REGULATIONS / I REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE
FOLLOWING BRITISH STANDARDCODES OF PRACTICE - BS 6172, BS 5440 PART2, BS 6891"
"THISAPPLIANCE MUST BE INSTALLED INACCORDANCE WITH THE RULES IN FORCE”
"MUST BE INSTALLED INAWELLVENTILATEDAREA.Ventilation requirements ie. B.S. 5440.”
We strongly recommend having a competent professional install this equipment. Such a person should be
familiar with local gas regulations. A gas company representative should approve the completed
installation.
Caution:
CANADIAN INSTALLATION MUST COMPLY WITH THE CANADIAN ELECTRICAL CODE, CSA C22.2
ASAPPLICABLE.
European Community Installation Instructions:
IMPORTANT:
THESE UNITSARE SUITABLE FOR INSTALLATION ONNON-COMBUSTIBLE SURFACES ONLY.
!
!