APW Wyott VSX Toaster User Manual


 
“If you like to keep
your counter clean,
APW Wyott also
offers a bun catcher.
This is a bun chute
that will catch the
crumbs that fall down
the bun chute. The
bun catcher is part
number 81699002.”
FIGURE 5:
VSX-20 W/BUN CATCHER
FIGURE 4: TYPICAL
TOASTER OPERATION
HEEL IN
BACK
CROWN
IN FRONT
BUN
DISCHARGE
Status,Alarm, and Error Messages (See Figure 3)
rdY
Lo
Hi
Prb
HIE
Control is at set point and the toaster is ready for operation.
Actual temperature is below set point. After toaster has reached “rdY,” then this indicates
that the platen is less than 50°F below the set point (toocold).
Actual temperature is above set point.
The temperature probe (sensor) is disconnected or defective.
Actual temperature is at least 50°F above set point, indicating that there isa controller error.
VSX-10 Temperature Control (See Figure 6)
Operation of Controller (See Figure 6)
NO HEAT: When the knob is pointed here, all heat is cut off from the
platen. The conveyors will run, but the platen will not heat.
PILOT: Illuminated when power is being applied to heater.
KNOB: Used to select the set point. Graduations are °F.
POWER: Main power supply to the toaster.
1. Make sure that all the doors are closed and the lid is on. (It
should look like the photograph onthe cover.)
2. Make sure toaster is plugged in to the correct voltage. The
voltage of the toaster is written on the data plate. The
data plate is located on the back of the toaster near the
cord.
3. Turn the toaster on (POWER). “|” is on and “O” is off.
4. Turn the dial to the desired set point. APW recommends
that you set it to 600°F or below. If the dial is set to “NO
HEAT” then the toaster will run normally except that there
will be no more heat supplied to the toaster. The toaster will
cool down to room temperature.
5. Whenever heat is applied to the platen, the PILOT light will
be illuminated. When the pilot light has cycled a couple of
times (turned off and on, twice), then the toaster is ready
for toasting. This takes 10-15 minutes.
FIGURE 6:
VSX-10
TEMP. CONTROL
PILOT