3
AUS
Electrical connection
! Ovens equipped with a three-pole power supply
cable are designed to operate with alternating
current at the voltage and frequency indicated on
the data plate located on the appliance (see below).
Fitting the power supply cable
1. Open the terminal board by inserting a
screwdriver into the
side tabs of the cover.
Use the screwdriver as
a lever by pushing it
down to open the cover
(see diagram).
2. Install the power
supply cable: loosen
the cable clamp screw
and the three screws for
the
wire contacts L-N-
and then fix the wires
underneath
the heads of the
screws, respecting the
colour coding: Blue (N)
Brown (L) Yellow-Green
(see figure).
3. Fix the cable in
place by fastening the
clamp screw.
4. Close the terminal board cover.
Connecting the power supply cable to the
electricity mains
Install a standardised plug corresponding to the
load indicated on the data plate (see opposite).
The appliance must be directly connected to the
mains using an omnipolar switch with a minimum
contact opening of 3 mm installed between the
appliance and the mains. The switch must be
suitable for the charge indicated and must comply
with current electrical regulations (the earthing wire
must not be interrupted by the switch). The supply
cable must be positioned so that it does not come
into contact with temperatures higher than 50°C at
any point (the back panel of the oven, for example).
! The installer must ensure that the correct electrical
connection has been performed and that it is fully
compliant with safety regulations.
Before connecting the appliance to the power
supply, make sure that:
• The appliance is earthed and the plug is compliant
with the law.
• the socket can withstand the maximum power of
the appliance, which is indicated on the data
plate (see below);
• the voltage is in the range between the values
indicated on the data plate (see below);
• the socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use extension cords or multiple sockets.
! Once the appliance has been installed, the power
supply cable and the electrical socket must be
easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced
by authorised technicians only (see Assistance).
! The manufacturer declines any liability should
these safety measures not be observed.
APPLIANCE SPECIFICATIONS
width 43.5 cm
height 41 cm
depth 41 cm
Volume*
Dimension*
74 l
Electrical
connections
voltage: 220 - 240 V~ 50/60 Hz
maximum power absorbed
2600 W (see data plate)
ENERGY
LABEL
Directive 2002/40/EC on the label
of electric ovens.
Standard EN 50304
Declared energy consumption for
Forced convection Class –
heating mode: ECO
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
– 2004/108/EEC dated 15/12/04 and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments
- 2002/96/EC and subsequent
amendments.
1275/2008 Standby/off mode
width 45.6 cm
height 41 cm
depth 41 cm
Volume**
Dimension**
77 l
* Only for models with drawn rails.
** Only for models with wire rails.
N